All toolsFree calculator
Finished-hole calculator
Enter a drill size, plating thickness and tolerance to get the finished hole size, its range and whether a lead will fit.
Finished hole
finished = drill − 2 × plating ± tol
Finished hole (nominal)
Pass0.95 mm
37.4 mil
At least 0.2 mm between the lead and the smallest hole: easy to insert and solder.
- Smallest
- 0.875 mm
- Largest
- 1.025 mm
- Lead clearance at smallest
- 0.275 mm
The rule
A plated hole ends up smaller than the drill, because copper is plated onto the wall all the way round. The fab then guarantees the finished size only within a tolerance, so plan for the smallest hole you might get.
For through-hole parts, leave clearance between the lead and that smallest hole so the part goes in and solder can flow. Most fabs work the other way round: you give them the finished size and they pick a drill about 0.1 mm larger.
Formula
finished = drill − 2 × plating range = finished ± tolerance fit = (finished − tolerance) − lead fit ≥ 0.20 mm pass fit ≥ 0.15 mm tight
Typical values and sources
- IPC-6012: average hole-wall copper of 20 µm for Class 2 and 25 µm for Class 3.
- ±0.075 mm (3 mil) is a common finished-hole tolerance for plated holes; non-plated holes are often ±0.05 mm. Typical values.
- IPC-2222 suggests hole-minus-lead allowances of roughly 0.15 to 0.25 mm, depending on producibility level.
Limits differ between fabs. Treat these as starting points and check your fab's capability page.
More calculators
- Stencil area-ratio calculatorAperture size and foil thickness to area ratio, with the 0.66 release guideline.
- Via aspect-ratio calculatorBoard thickness and drill size to aspect ratio, against common fab limits.
- Copper-weight converteroz/ft², µm and mil, with typical finished thickness.