Skip to content

All toolsFree calculator

Finished-hole calculator

Enter a drill size, plating thickness and tolerance to get the finished hole size, its range and whether a lead will fit.

Finished hole

finished = drill − 2 × plating ± tol

mm
mm

Typically 20–25 µm (0.8–1 mil). Use 0 for a non-plated hole.

mm

Often ±0.075 mm (3 mil) for plated holes.

mm

For a square pin, use the diagonal.

Finished hole (nominal)

Pass

0.95 mm

37.4 mil

At least 0.2 mm between the lead and the smallest hole: easy to insert and solder.

Smallest
0.875 mm
Largest
1.025 mm
Lead clearance at smallest
0.275 mm

The rule

A plated hole ends up smaller than the drill, because copper is plated onto the wall all the way round. The fab then guarantees the finished size only within a tolerance, so plan for the smallest hole you might get.

For through-hole parts, leave clearance between the lead and that smallest hole so the part goes in and solder can flow. Most fabs work the other way round: you give them the finished size and they pick a drill about 0.1 mm larger.

Formula

finished = drill − 2 × plating
range    = finished ± tolerance
fit      = (finished − tolerance) − lead

fit ≥ 0.20 mm   pass
fit ≥ 0.15 mm   tight

Typical values and sources

  • IPC-6012: average hole-wall copper of 20 µm for Class 2 and 25 µm for Class 3.
  • ±0.075 mm (3 mil) is a common finished-hole tolerance for plated holes; non-plated holes are often ±0.05 mm. Typical values.
  • IPC-2222 suggests hole-minus-lead allowances of roughly 0.15 to 0.25 mm, depending on producibility level.

Limits differ between fabs. Treat these as starting points and check your fab's capability page.